Debugger Dangers – Part 2

About 5 years ago I wrote about the risks that connecting to Oracle processes via debuggers may cause and what are (in my opinion) the safer and less safer options for taking stack samples from running Oracle processes.

In the end of that article I listed different options for getting a stack traces and whether they were safe or not.

For example, ORADEBUG-based process stack traces (DUMP ERRORSTACK, SHORT_STACK and event the process/system state dumps (at level 256 or higher) are not 100% safe – because they alter the execution path of the process they attached to. Your process may crash or get some error if you hit a bug (of course once you patch/fix the bug, you’ll be fine again – until you may hit the next bug).

An example bug is this:

Bug 15677306 : SUNBT6994922 ORACLE LOGWRITER HARD HANG WHEN SIGUSR INTERRUPTS LIBAIO

LGWR may hang when SIGUSR interrupts libaio (that’s what LGWR uses for asynchronous IO). And if LGWR is hung – your whole instance will be hung pretty soon. But what does the SIGUSR signal have to do with Oracle? Well, that’s exactly the signal what ORADEBUG sends to the process it has attached to, to notify it about some debug/dump work it needs to do. And apparently receiving or handling such a signal (jumping into some stack dump function), when being in libaio codepath causes an issue.