In the previous post I explained how to list Exadata disk layout and topology details with the exadisktopo scripts, in this post I’ll introduce one celldisk overview script, which I use to quickly see the celldisk configuration, specs and error statuses. The cellpd.sql script (Cell Physical Disk) will show the following output:

SQL> @exadata/cellpd.sql
Show Exadata cell versions from V$CELL_CONFIG....

DISKTYPE             CELLNAME             STATUS                 TOTAL_GB     AVG_GB  NUM_DISKS   PREDFAIL   POORPERF WTCACHEPROB   PEERFAIL   CRITICAL
-------------------- -------------------- -------------------- ---------- ---------- ---------- ---------- ---------- ----------- ---------- ----------
FlashDisk            192.168.12.3         normal                      183         23          8
FlashDisk            192.168.12.3         not present                 183         23          8                     #ff0000;">3
FlashDisk            192.168.12.4         normal                      366         23         16
FlashDisk            192.168.12.5         normal                      366         23         16
HardDisk             192.168.12.3         normal                    22352       1863         12
HardDisk             192.168.12.4         normal                    22352       1863         12
HardDisk             192.168.12.5         normal                    22352       1863         12

Above you see that some of my Flash Disks are missing and before they went completely missing (because the Oracle Ninja removed them :) these disks indicated the “poor performance” status.

The cellpdx.sql script will display extended info for each celldisk, including disk model, firmware version, serial number and various error metrics. Warning, lots of wide output coming again: